At just 34-1/2' high, our 80% space-saving furnace is ideally suited to both new construction and replacements - models can fit into the space of virtually any furnace being replaced, including attics, crawl spaces and utility closets. Contractors will appreciate not just the small size, but also the number of installation options, including left- or right-side gas, and left- or right-side electric connections. Because of the small size, it's easy to handle, fitting easily through most doors and hallways.
- Comfort Aire Gas Furnace Parts
- Comfort Aire Conquest 90 Gas Furnace Manual Mobile Home
- Comfort Aire Conquest 90 Gas Furnace Manual And Schematics 58gs100
- Comfort Aire Conquest 90 Furnace
- Comfort Aire Gas Furnaces
- Comfort Aire Conquest 90 Gas Furnace Manual Download
- Comfort Aire Conquest 90 Gas Furnace Manual Pdf
AFUE ratings of 80% mean that nearly all the heat generated by the furnace is used to heat the home. In this time of soaring fuel prices, better utilization of natural resources can mean significant dollar savings.
The GUH Upflow/Horizontal Series comes in capacities ranging from 45,000 BTUH to 126,000 BTUH, while the GDD Downflow Series is available in 54,000 to 126,000 BTUH capacities.
Conquest 90 Gas Furnace Troubleshooting Manual plusair sm8 compressor manual comfort aire conquest 80 furnace manual kymco people 150 repair conquest 90 high efficiency gas furnaces - 17hp stratton manual conquest 80 flame sensor - home improvement - cola safety conquest 90 furnace - the inspector's journal. Oct 04, 2014 Buy Genuine HVAC Parts for Comfort-aire GLUA 90-E5A. It's Easy to Repair your HVAC. 23 Parts for this Model. Parts Lists, Photos, Diagrams and Owners manuals. COVID-19 NOTICE: Please allow 6 business days for your order to be shipped. Comfort Aire Furnaces Consumers Supply stocks Comfort-Aire furnaces, a leader in the heating industry. Shop below or call or text us at 312-666-6080 for more info. Jan 01, 2009 I also have a Conquest 90 furnace. I have had it about 4 years. For the last 6 weeks, I have been having trouble with the burner staying on. I have had heating technicians working on this and they are stumped. Platinum notes free download. Here is what happens. The ignitor comes on, then the burner ignites, ignitor goes out. 80% furnaces are fully convertible to either natural gas or propane, making them suitable for use in any area; Cabinets are constructed of corrosion-resistant galvanized steel; Certified to 1.4% cabinet air leakage; A951X Furnace System Features. Up to 96% AFUE single-stage for the level of comfort and efficiency you require.
Completely assembled, the furnace is ready for installation with a color-coded wiring harness and quick connect fittings. The integrated solid state control board speeds installation. Maintenance and servicing is easy to do with readily accessible components. Two-piece doors remove quickly and door screws are secured to the doors so they can't be lost after they're loosened. Diagnostic lights make it easy to troubleshoot operation.
80% furnaces are backed by a 20 year warranty on the aluminized steel heat exchanger and a 12 year warranty on other components. (Limitations apply; see printed warranty or website for details)
FEATURES
- Induced Draft Blower—Designed specifically to work with the tubular heat exchanger, it pulls hot combustion gases through the exchanger until the burner cycles off; heated air is locked in while cold air is locked out
- In-Shot Burner—Engineered to deliver to most efficient air/gas mixture, it allows heat to be generated efficiently
- Tubular Heat Exchanger—The heart of the furnace, the heat exchanger is made of heavy gauge aluminized steel, and carries a 20-year warranty
- Hot Surface Igniter—Quiet and automatic, it eliminates the need for a standing pilot light for improved efficiency
- Multi-Speed Direct Drive Blower—Delivers warm, filtered air through the ductwork to each room and also covers a wide range of cooling capacities; switches on PCB make it easy to select motor speed
- Integrated Control Board—Combines all controls and functions into one board for easy installation, and is designed to accept options such as an electronic air cleaner.
Two heat exchangers make this one of the most efficient furnaces on the market today.
Comfort Aire Gas Furnace Parts
At only 34-1/2' in height, the furnace is ideal for renovations and replacements, fitting in virtually any space where a furnace was previously installed, including basements and utility closets.
The furnace comes assembled and prewired, with a color-coded wiring harness and quick connect fittings. An integrated control board simplifies hook-ups, and all components are easy to reach. Because of its small size, the furnace is easy to handle, fitting through doors, halls and stairways.
The front panel door is easy to remove to access the filter, encouraging regular filter replacement
Comfort Aire Conquest 90 Gas Furnace Manual Mobile Home
The blower compartment has a sealed insulated door, while a sealed vestibule reduces burner and inducer sound levels for clean, efficient, quiet combustion.
The primary and secondary heat exchangers are covered by a limited lifetime warranty; other components are covered for 12 years. (Limitations apply; see Warranty for details.)
FEATURES
- Draft Inducer - Specifically designed for the tubular heat exchanger, it pulls hot combustion gases through the exchanger; heated air is locked in while cold air is locked out
- In-shot Burner - Engineered to provide the most efficient air/gas mixture for combustion, the design requires no manual adjustments to regulate the mix
- Primary Heat Exchanger - The patented tubular design is resistant to corrosion and thermal fatigue, and it is covered by a lifetime warranty
- Secondary Heat Exchanger - Unique heat recovery coil extracts additional heat, (which woud be lost by less efficient furnaces), stainless steel construction has a lifetime warranty
- Hot Surface Ignition - Silicon nitride type igniter is quiet and automatic, eliminating the need for a standing pilot light
- High Efficiency Blower - Three-speed blower delivers warm air throughout the house quietly and efficiently; direct drive system has no belts or pulleys to wear out
- Integrated Furnace Control - Controls are integrated into one board for fast, easy installation; features on-board diagnostics with easy to recognize fault codes
Our two stage furnace is designed for maximum convenience and optimum comfort. A conventional single stage furnace operates at high heat until the thermostat is satisfied, then shuts off until there's a demand for heat again. As a result the furnace is constantly cycling on and off. But with a two stage furnace, these temperature swings are virtually eliminated and your home stays at the comfort level you select.
Comfort Aire Conquest 90 Gas Furnace Manual And Schematics 58gs100
Most of the time, a two stage furnace operates in the low stage, delivering a gentle yet steady flow of heated air. When the weather turns really cold, the furnace automatically shifts into the high stage, providing the extra heat needed to keep the home at the desired comfort level. Whenever the furnace is in the low stage, energy is saved because the burner flame is smaller and the blower fans runs at a slower speed. Even in the high stage, with AFUE rating of 95%, utility costs are being saved.
The ECM variable speed blower motor adjusts the blower speed to deliver the airflow required by the system, resulting in more even temperatures than a single speed motor can provide. And because air is constantly being drawn across the filter, indoor air quality and humidity control are enhanced.
The primary and secondary heat exchangers are covered by a limited lifetime warranty; other components are covered for 12 years. (Limitations apply; see 'Warranty' for details)
FEATURES
- Quiet Operation—Sealed door and cabinet insulation locks in heat and sound; sealed vertibule reduces burner and inducer sound levels; ECM blower motor makes this one of the quietest furnaces on the market
- Extraordinary Efficiency—Two heat exchangers deliver 95%+ of the heated air to the home; the ECM blower motor may give up to 1 SEER point gain in cooling efficiency
- ECM Blower Motor—Runs at a variety of speeds to match the load demand, for efficiency and quiet operation; constant airflow through a wide vareity of ductwork conditions reduces temperature stratification while improving indoor air quality
- Hot Surface Igniter—Silicon nitride type igniter is automatic, eliminating the need for a standing pilot light
- Designed for Long Life—Primary heat exchanger is made of heavy gauge aluminized steel and secondary heat exchanger is made of stainless steel; cabinet is steel with corosion resistant finish
- Thermostat—Can be used with either a single or two-stage thermostat; two stage is recommended for optimal efficiency (not included with furnace)
EFFICIENCY
- Up to 92.1%
- All sizes meet ENERGY STAR® South regional standards.
PERFORMANCE
- compatible
TECHNOLOGY
- Single-stage gas valve
- Multi-Speed ECM blower motor
- Pilot-free, hot surface PowerHeat™ ignition
- Single speed inducer motor
- Aluminized steel clamshell-style primary
- Stainless steel fin-and-tube design secondary heat exchanger
- Recommended controls: Performance™ Edge® relative humidity or ComfortZone™ II thermostats
CAPACITIES
- 40,000-120,000
Comfort Aire Conquest 90 Furnace
INSTALLATION
![Comfort aire oil furnaces Comfort aire oil furnaces](https://img.scgpix.com/listimg/img1_0915/19/img_5UgfgBlsID.jpg)
- Flexible installation: , or horizontal
- Versatile venting for tight-fit applications
REQUIREMENTS
- 115 V
- .5' gas connection
- Convertible to Liquid Propane (LP)
AESTHETICS
- 20-gauge, galvanized steel with appliance finish
- Baked on urethane base coat and polyester top coat paint in taupe metallic
- Dimensions in upflow position: 35'H x width varies by size: 14.2-24.5' x 30'D
Comfort Aire Gas Furnaces
FOR CALIFORNIA RESIDENTS
Comfort Aire Conquest 90 Gas Furnace Manual Download
Comfort Aire Conquest 90 Gas Furnace Manual Pdf
- For installation in SCAQMD only: This furnace does not meet the SCAQMD Rule 1111 14 ng/J NOx emission limit, and thus is subject to a mitigation fee of up to $450. This furnace is not eligible for the Clean Air Furnace Rebate Program: www.CleanAirFurnaceRebate.com.